NSX-T 3.1: Sharing Transport VLAN between Host and Edge Nodes

$
0
0

When NSX-T 3.1 was released a few days ago, the feature that I was most looking for was the ability to share Geneve overlay transport VLAN between ESXi transport nodes and Edge transport nodes.

Before NSX-T 3.1 in a collapsed design where Edge transport nodes were running on ESXi transport nodes (in other words NSX-T Edge VMs were deployed to NSX-T prepared ESXi cluster) you could not share the same transport (TEP) VLAN unless you would dedicate separate physical uplinks for Edge traffic and ESXi underlay host traffic. The reason is that the Geneve encapsulation/decapsulation was happening only on the physical uplink in/egress and that point would be skipped for intra-host datapath between the Edge and host TEP VMkernel port.

This was quite annoying because the two transport VLANs need to route between each other at full jumbo MTU>1600 frame size. So in lab scenarios you had to have additional router taking care of that. And I have seen multiple time issues due to  misconfigured router MTU size.

After upgrading my lab to NSX-T 3.1 I was eager to test it.

Here are the steps I used to migrate to single transport VLAN:

  1. The collapsed Edge Nodes will need to use trunk uplinks created as NSX-T logical segment. My Edge Nodes used regular VDS port group so I renamed the old ones in vCenter and created new trunks in NSX-T Manager.
  2. (Optional) Create new TEP IP Address Pool for the Edges. You can obviously use the ESXi host IP Pool as now they will share the same subnet, or you can use static IP addressing. I opted for new IP Address Pool with the same subnet as my ESXi host TEP IP Address Pool but a different range so I can easily distinguish host and edge TEP IPs.
  3. Create new Edge Uplink Profile VLAN to match the ESXi transport VLAN.
  4. Now for each Edge node repeat this process: edit the node in the Edge Transport Node Overview tab, change its Uplink Profile, IP Pool and uplinks to the created ones in steps #1, #2 and #3. Refresh and observe the Tunnel health.
  5. Clean up now unused Uplink Profile, IP Pool and VDS uplinks.
  6. Deprovision now unused Edge Transport VLAN from physical switches and from the physical router interface.

During the migration I saw one or two pings to drop but that was it. If you see tunnel issues try to put the edge node briefly into NSX Maintenance Mode.